General parameter

General Modbus-parameter

Description (HTML)


Note


Documents

SolaX Power X3 Hybrid Inverter Registerlist

Device Image (JPEG)

No image uploaded.

Device Description File



Profile

INDEX NAME DIRECTION REGISTER COUNT FUNCTION TYP CONVERTION ENUMS UNIT
1 radiator_temperature READ 8 1 fc4 int16 °C
2 run_mode READ 9 1 fc4 ui16 0: waiting, 1: checking, 2: normal, 3: fault, 4: permanent fault, 5: update, 6: off-grid waiting, 7: off-grid, 8: self testing, 9:idle, 10: standby
3 batvoltage_charge1 READ 20 3 fc4 int16 x/10 V
4 batcurrent_charge1 READ d3 int16 x/10 A
5 batpower_charge1 READ d3 int16 x/1000 kW
6 BMS_connect_state READ 23 1 fc4 ui16 0/1 0: disconnected, 1: connected
7 battery_capacity READ 28 1 fc4 ui16 %
8 BMS_chargemaxcurrent READ 36 3 fc4 ui16 x/10 A
9 BMS_dischargemaxcurrent READ d8 ui16 x/10 A
10 BMS_battery_capacity READ d8 ui16 x/1000 kWh
11 feedin_power READ 70 2 fc4 si32 x/1000 kW (positive= generate power, negative= consume power)
12 feedin_energy_total READ 72 2 fc4 ui32 x/100 kWh
13 consumed_energy_total READ 74 2 d12 ui32 x/100 kWh
14 Etoday_togrid READ 80 1 fc4 ui16 x/10 kWh
15 Etotal_togrid READ 82 2 fc4 ui32 x/10 kWh
16 lock_state READ 84 1 fc4 ui16 0/1 0: locked, 1: unlocked
17 grid_voltage_R READ 106 4 fc4 ui16 x/10 V
18 grid_current_R READ d17 int16 x/10 A
19 grid_power_R READ d17 int16 x/1000 kW
20 grid_frequency_R READ d17 ui16 x/100 Hz
21 grid_voltage_S READ 110 4 fc4 ui16 x/10 V
22 grid_current_S READ d21 int16 x/10 A
23 grid_power_S READ d21 int16 x/1000 kW
24 grid_frequency_S READ d21 ui16 x/100 Hz
25 grid_voltage_T READ 114 4 fc4 ui16 x/10 V
26 grid_current_T READ d25 int16 x/10 A
27 grid_power_T READ d25 int16 x/1000 kW
28 grid_frequency_T READ d25 ui16 x/100 Hz
29 off-grid_voltage_R READ 118 3 fc4 ui16 x/10 V
30 off-grid_current_R READ d29 ui16 x/10 A
31 off-grid_poweractive_R READ d29 int16 x/1000 kW
32 off-grid_voltage_S READ 122 3 fc4 ui16 x/10 V
33 off-grid_current_S READ d32 ui16 x/10 A
34 off-grid_poweractive_S READ d32 int16 x/1000 kW
35 off-grid_voltage_T READ 126 3 fc4 ui16 x/10 V
36 off-grid_current_T READ d35 ui16 x/10 A
37 off-grid_poweractive_T READ d35 int16 x/1000 kW
38 feedinpower_Rphase READ 130 2 fc4 ui32 x/1000 kW
39 feedinpower_Sphase READ 132 2 fc4 ui32 x/1000 kW
40 feedinpower_Tphase READ 134 2 fc4 ui32 x/1000 kW
41 EchargeToday READ 145 1 fc4 ui16 x/10 kWh
42 EchargeTotal READ 146 2 fc4 ui32 x/10 kWh
43 SolarEnergyToday READ 148 1 fc4 ui16 x/10 kWh
44 SolarEnergyTotal READ 149 2 fc4 ui32 x/10 kWh