Amtron Charge Control
Description
MENNEKES AMTRON Charge Control
This DDF enables the integration of the MENNEKES AMTRON Charge Control into the E-Mobility system via Modbus TCP. This enables dynamic charging power control, energy monitoring and integration with external energy management systems (EMS).
The wallbox is designed for intelligent charging applications and supports both single-phase and three-phase installations. In addition to the AMTRON Charge Control, the MENNEKES AMEDIO Professional and MENNEKES AMTRON Professional are also supported.
Requirements
The following requirements must be met to use this DDF:
- a compatible MENNEKES AMTRON Charge Control, AMEDIO Professional or AMTRON Professional
- a functioning network connection between the wallboxes and the E-Mobility system
- enabled and properly configured Modbus TCP communication
- the IP address of each wallbox to be integrated
Configuration on the Controller
Configuration directly in the Device Station:
| Parameter | Description | Example |
|---|---|---|
| SLAVES | Contains the IP addresses of the wallboxes to be integrated. Up to 10 wallboxes per Device Station can be integrated using this DDF. Enter the individual IP addresses separated by commas. | 192.168.1.101,192.168.1.102,192.168.1.103 |
Enter the IP addresses of all required wallboxes in SLAVES using the following format:
<IP Address 1>,<IP Address 2>,...
Usage
After successful setup, the wallboxes can be integrated into the E-Mobility system via the DDF and used for various applications.
- Dynamic charging power control: Charging power can be adjusted according to the available electrical power, for example as part of a load management system.
- Energy monitoring: Available energy data can be collected and used for analysis.
- Energy management: The wallboxes can be integrated with external energy management systems (EMS).
- RFID authentication: Depending on the wallbox equipment, RFID can be used for authentication and to start or stop charging sessions.
Important Notes
Up to 10 wallboxes per Device Station can be integrated using this DDF. Each wallbox must be reachable via its IP address and configured for Modbus TCP communication.
RFID functionality depends on the equipment and configuration of the respective wallbox.
General Info
| Manufacturer | Type | Protocol | Model | Version | ID |
|---|---|---|---|---|---|
| Mennekes | Wallbox | MODBUS TCP (DDF) | 1 | 1 | 0x0A00001100010100 |
Documents
DDF Items
| ID | Name | Unit | Type | Direction |
|---|---|---|---|---|
| 0 | Vehicle state | 65= A (no car), 66= B (car connected), 67= C (charging), 68= D (charging with ventilation), 69= E (error), 70= F (communication error) | int | IN |
| 1 | Power L1 | kW | real | IN |
| 2 | Power L2 | kW | real | IN |
| 3 | Power L3 | kW | real | IN |
| 4 | Voltage L1 | V | real | IN |
| 5 | Voltage L2 | V | real | IN |
| 6 | Voltage L3 | V | real | IN |
| 7 | Ampere L1 | A | real | IN |
| 8 | Ampere L2 | A | real | IN |
| 9 | Ampere L3 | A | real | IN |
| 10 | Power Total | kW | real | IN |
| 11 | Energy Total | Wh | real | IN |
| 12 | Power unit | kW | string | IN |
| 13 | Energy unit | Wh | string | IN |
| 14 | Charge setpoint | A | real | OUT |
| 15 | CP available | int | OUT | |
| 16 | Phase | int | IN | |
| 17 | Phases available | int | IN | |
| 18 | RFID | string | IN | |
| 19 | RFID_START | string | OUT | |
| 20 | RFID_STOP | string | OUT | |
| 200 | Quality | int | IN | |
| 201 | Timestamp | datetime | IN | |
| 204 | Info | string | IN |